Many local codes require that exhaust fans installed in fire-rated ceilings must be protected by dampers, which, in case of fire, protect against the spread of heat and flame.
Being fire-rated means the ability of a wall, floor/ceiling, or roof/ceiling to withstand the effects of fire for a specified period of time. Broan ceiling radiation dampers are designed to protect the openings in 1-, 2-, or 3-hour fire-rated floor-ceiling and roof-ceiling designs.
When the temperature of the air passing through the damper exceeds 165°F, the fusible link melts and the thermal fabric across the damper closes automatically to interrupt the airflow by becoming a flame and heat barrier, preventing rapid spread of fire to other areas.
Features:
| • |
Housings and finishes (motor assembly and grille) sold separately in units of four per carton - purchase housings for rough-in and blower assemblies/grilles later for finishing.
Model RDH with Model HD50RDF is ENERGY STAR® qualified. |
| • |
UL classified (UL standard 555C) for use in 1-, 2-, or 3-hour fire-rated floor-ceiling and roof-ceiling designs. |
| • |
Warnock Hersey Listing allows use in combustible ceilings with ducted fans. |
| • |
High temperature, non-asbestos, reinforced fiber thermal fabric. |
| • |
Galvanized steel frame. |
| • |
165°F fusible link. |
| • |
Stainless steel negator-type closure spring. |
| • |
Available from 50 CFM to 110 CFM. |
| • |
Radiation damper comes attached to housing. |
| • |
Blower assembly will fit into housing without the removal of the radiation damper - one less step in installation process. |
Specifications:
CFM: 50
Sones: 1.5
Bath Sq.Ft.: 100