The PMD-243-HDX Dual-Zone configuration includes two (2) 12,000 BTU indoor units and one (1) 27,000 BTU outdoor unit. Total cooling capacity - 22,929 BTU's/hr. The Pridiom PMD-243-HDX Dual Zone Cooling System with Heat Pump is designed to quietly cool 2 separate areas. The attractive light-weight air handlers mount on the wall for discreet yet efficient cooling or heating, while the compressor and condenser coil are outside. The Pridiom PMD-243-HDX Dual Zone Inverter system utilizes Eco-Friendly R410-A Refrigerant which does not deplete the ozone layer and helps to preserve our environment. The PMD-243-HDX covers 2 areas up to 500 square feet each.
Description:
Ductless Split Dual-Zone Air Conditioner / Heat Pump systems offer wide versatility in solving your cooling and heating requirements. The Indoor unit (evaporator) is mounted inside the room and is connected to the outdoor unit (condenser) via small refrigerant lines that run through a three inch opening in the wall or ceiling. Since multi-zone inverter systems require no ductwork, installation is simple. fast & efficient. There is no need to use up window space or cut large openings in existing walls. Since the compressor is located in the outside, operating noise inside is virtually eliminated. The indoor unit is designed to provide whisper quiet operation while delivering comfort throughout the room(s). Our ductless multi zone mini split systems deliver the unmatched comfort of a traditional split system to two rooms with only one outdoor unit. And, because each zone operates independently (with it's own remote control), people in each room will all enjoy the temperature that makes them feel the most comfortable. Pridiom Multi Zone air conditioners / heat pumps are perfect for residential, commercial, and institutional building applications. The most common applications are in multi-family housing or as retrofit add-ons to houses with "non-ducted" heating systems, such as hydronic (hot water heat), radiant panels, and space heaters (wood, kerosene, propane). Dual zone inverter air conditioning /heat pump systems can also be a good choice for room additions and small apartments, where extending or installing distribution ductwork (for a central air-conditioner or heating systems) is not feasible. Applications in other types of buildings include: recording studios, school classrooms; perimeter cooling for office buildings; additional cooling for restaurant kitchens; and cooling for small offices within larger spaces, such as arenas, warehouses, and auditoriums.
Features:
•Advanced Inverter Technology
•Wireless Remote Control included with each indoor unit
•Dehumidification Capability
•Auto Swing Louver
•Auto Restart
•Auto Mode
•Temperature Display on Indoor Unit
•Sleep Model
•Low Ambient Operation
•Pridiom Ductless mini-split heat pump systems use Advanced Inverter Technology to constantly adjust output to maximize comfort and minimize energy costs.
•Warranty - 5 Years compressor - 3 Years parts - 1 Year limited labor. All units require professional HVAC contractor installation. Installer must be licensed. The warranty is for manufacturing defects only - If a defect is the result of improper installation, the repair will not be covered by the warranty. Installer must be able to provide proof of licensing if requested by Pridiom.
The Pridiom PMD-243-HDX Dual Zone Mini-Split includes 2 installation kits. Each installation kit includes;
•25' Double Insulated Line-set
•25' Wiring Harness for complete installation.
•Wall Sleeve
•Vinyl wrap
Specifications:
| | Indoor Unit #1 & #2 | Outdoor Unit |
| Cooling Capacity | 12,000 BTU/hr | 27,000 BTU/h |
| Inverter Capacity Range | | 7,000 ~ 27,000 |
| Heating Capacity | 13,000 BTU/hr | 24,600 BTU/h |
| Inverter Capacity Range | | 10,000 ~ 30,000 |
| Dehumidifier Capacity | 2.11 pints/hr | |
| Voltage | 208/230-60-1 | 208/230-60-1 |
| Input Current (A) Rated/Max | 0.3 | 9.7 / 16 |
| Max Overload Protection (A) | | 20 |
| Power Use (KW) Rated/Max | | 1.15 / 3.10 |
| Fan Speeds L-M-H (RPM) | 900-1000-1250 +Auto | 3 +Auto |
| Air Circulation L-M-H (CFM) | 230-284-383 | |
| Noise Level L-M-H dB(A) | 28-35-40 | 55 |
| Connection Method | Flare | Flare |
| Pipe Size | 1/4" - 1/2" | 1/4" - 3/8" |
| Max. Pipe Length | | 82 ft. |
| Service Port Connection In. (UNF) | | 5/16 (1/2 - 20) |
| SEER | | 16.0 |
| HSPF | | 8 |
| COP | | 3.64 |
| EER Cooling | | 9.8 |
| Operating Range - Cool | | 32° ~ 122° |
| Operating Range - Heat | | 5° ~ 75° |
| Dimensions - WxHxD | 33-1/4" x 11-1/4" x 6-1/2" | 33-1/4" x 27-3/8" x 13-1/4" |
| Weight | 22 lbs. | 123 lbs. |
| Refrigerant | R-410A | R-410A |
| Approvals | ETL, AHRI Performance Certified 210/240 | ETL, AHRI Performance Certified 210/240 |
Pridiom PMD243HDX Reviews & Ratings
Pridiom PMD243HDX Reviews
Mini Split Air Conditioner Systems Pridiom PMD243HDX
| 5 Star: | | 0 Reviews |
| 4 Star: | | 1 Reviews |
| 3 Star: | | 0 Reviews |
| 2 Star: | | 0 Reviews |
| 1 Star: | | 0 Reviews |
|
Average Customer Review:

|
Share your thoughts with other customers:
You will need Adobe Acrobat Reader to view and print pdf files.